Grundfos sololift2 c-3 manual. English GB 2 These installation and operating instructions describe Grundfos Sololift C Sections give the information necessary to be able to unpack, install and start up the product in a safe way. Sections give important information about the. Sections give important information about the product, as well as information on service, fault finding and disposal of the product.
General information Symbols used in this. Sololift2 C-3 Description Technical data TM04 Suitable for pumping grey wastewater from a washing machine, dishwasher, bath tub, cabinet shower, washbasin or kitchen sink. General information Hazard statements. The Met opens Charles James: Beyond Fashion, a tribute to the designer who believed he was the greatest couturier who ever lived, and quite possibly was. Then disconnect the Electrical parts must only be serviced by Grundfos or water supply to all units connected.
Page 5: Wc-1, Wc-3, Cwc-3 5. Remove the cover. See section 5. Disconnect pressure switch plug pos. Remove screw pos. Clean the sealing face of the tank top and the outer sealing 5. Lubricate the O-ring on the motor flange and the sealing face 2.
Page 7: Removing The Cover 6. C-3, D-2 6. Lift the cover free in one end and remove it. Caution Take care not to break the two locking pins.
Fit the cover. The locking pins must engage with tank top pos. Page 8: Replacing The Impeller 6. See section 6. Remove motor flange pos. Remove screws pos. Page 9: Fault Finding 7. Fault finding Warning Remove the fuse, pull out the plug, or switch off the power supply. Make sure that the power supply cannot be accidentally switched on.
All rotating parts must have stopped moving. The product must only be serviced by trained service personnel. Page Wiring Diagrams 8. Page Exploded Views 9. Exploded views 9. Page Wc-3 9.